Videos

Image stabilization during first light at CFHT

25/04/2018 – File size: 0.70 MB Download file

Gl 410, a red dwarf of 6th magnitude (at 1.7µm) with a surface temperature of 3200 °C, is one of the targets chosen for these guiding tests. Although the image of the star is distorted as a result of atmospheric turbulence, the 50 Hz tip-tilt system was shown to accurately maintain it on the entrance aperture at a precision of better than 0.01” rms on 1 min intervals (© C. Moutou – CNRS/CFHT)

Timelapse of the spectrograph closure at CFHT

16/02/2018 – File size: 3.88 MB Download file

Closing the SPIRou spectrograph prior to the first cryogenic cycle at CFHT
(© S. Chastanet – CNRS/OMP)

Timelapse of the spectrograph preparation at CFHT

15/02/2018 – File size: 2.56 MB Download file

Preparing the SPIRou spectrograph prior to the first cryogenic cycle at CFHT
(© S. Chastanet – CNRS/OMP)

Image stabilization during artificial star observations

26/11/2017 – File size: 8.8 MB Download file

The SPIRou Image Stabilization Unit (ISU) in action at 50Hz: the left panel shows the image of the artificial star kept well centered on the instrument entrance aperture while the star itself is moving randomly by as much as 0.5’’ rms over the exposure, whereas the right panel shows the ISU correction needed to maintain the artificial star well centered (green ‘+’ signs for the 50 most recent corrections over the last second). Sudden image shifts occurring every minute (at t=41s in this movie) simulate the decentering effect of the wind, which the ISU is found to correct well. In average over the whole exposure the image of the artificial star is found to be centered on the hole down to a precision of 0.005” to 0.01’’ rms, 5-10x better than the technical requirement.
(©S.Baratchart – IRAP/OMP)

Timelapse of the spectrograph closing before cooling

03/05/2017 – File size: 8.60 MB Download file

Closing of the SPIRou spectrograph before a new cooling cycle, in Toulouse @IRAP/OMP
(©SPIRou – IRAP/OMP)

Timelapse of the cryostat assembly before cooling

28/09/2016 – File size: 10.00 MB Download file

A new time lapse of the spectrograph cryo-mechanics full installation and cryostat closing in the SPIRou dedicated clean room, IRAP/P2IS plateform in Toulouse
(©S.Etcheverry – OMP)

Timelapse of the spectrograph installation

28/09/2016 – File size: 7.05 MB Download file

Time lapse of the spectrograph cryo-mechanics installation at the IRAP/P2IS plateform, in Toulouse
(©N.Striebig-CNRS/OMP)